RAS RF Admittance Level Switch
RF admittance level switch with measuring, shielding and grounding electrodes, outputting a switch signal when the electrode is covered by material.
Technical data
| Process Temperature: | -40°C ~ 1200°C (special customization available for process temperature above 230°C) | Process Pressure: | -1 kgf/cm² ~ 63 kgf/cm² |
| Resolution: | 0.01pF | Stability: | 0.01%/℃ |
| Load Capacity: | ≤51 Nm (lateral load capacity of normal temperature RF admittance); ≤215 Nm (lateral load capacity of high temperature RF admittance); ≤20 kN (dragging force of wirerope-type RF admittance) |
Features & Benefits
Highly-universal
Able to measure the level of liquid and material and extensively applicable to flying ash, granular, powder, liquid, viscous, conductive, non-conductive materials; suitable for measurement under varying temperatures, pressures and media, as well as applicable under corrosive and impact-prone harsh conditions
Anti-buildup of Material
A dedicated circuit design allows the measuring circuit to ignore the material buildup on the probe and provides automatic correction
Maintenance-free
No moving components during measurement; no mechanical damage concern; free from maintenance
Anti-disturbance
Contacting measurement with strong disturbance immunity, overcoming the impacts from steam, foam and stirring
Easy installation
Installed with thread or flange in a simple, easy and quick way