MFD Slurry Electromagnetic Flowmeter

The MFD Series Electromagnetic Flowmeter is designed specifically for liquid-solid two-phase flows such as pulp and ore slurry. It employs multi-frequency excitation and anti-interference technology to deliver stable measurement of high-concentration slurries with fast response.

Technical data

Accuracy: Class 0.5 Process Temperature: -25°C to +180°C (sensor side)
Process Pressure: Up to 42 MPa Nominal Size: DN25–DN600
Ingress Protection: Sensor: IP68; Converter: IP67 Applicable Concentration: 5%–60%
Response Time: ≥0.8 s

Features & Benefits

Purpose-Built for Slurry Two-Phase Flow, Handles High Solids and Low Conductivity

The MFD series is a slurry-type electromagnetic flowmeter designed specifically for pulp, mud, mineral slurry, and coal-water slurry. It tolerates solids content (by volume) up to 70%—seven times that of standard series (≤10%)—and gas content up to 5%, with a minimum measurable conductivity as low as 5 µS/cm. The measuring tube has no flow restrictions or moving parts, so it causes no additional energy loss and will not clog—ideal for solid-liquid two-phase flow. From leaching and thickening to centrifugal separation, one meter covers the entire slurry process, eliminating the direct failure caused by exceeding the standard solids limit.

High-Frequency Excitation + High-Speed Sampling + Adaptive Filtering for Slurry Noise Suppression

Multi-frequency square-wave excitation, 19,200 SPS high-speed sampling, and DSP digital filtering work in tandem with comb-band filtering, sliding-average smoothing, noise correction, and spike rejection. The adaptive filter automatically adjusts strength based on real-time signal-to-noise ratio—tightening filtering at low flow and high noise, relaxing it at high flow and strong signal—balancing stability and response.

Response as Fast as 0.8 s for Process Interlock Control

Multi-frequency excitation detects flow changes rapidly, with a response time of 0.8 s—meeting the <1 s requirement for process interlock control. Adaptive damping keeps readings stable even under fluctuating flow conditions.

High Accuracy, Bidirectional Measurement, Calibration-Free Transmitter Interchangeability

Accuracy 0.5 class, repeatability ≤±0.06% to ±0.16%; excitation coil insulation resistance up to 500 MΩ for high SNR. DSP signal processing resolves micro-flow signals with startup velocity as low as 6 mm/s (depending on size). Supports bidirectional flow with configurable zero on reverse flow. Standard-simulated sensor calibration means transmitter replacement requires no recalibration against a flow standard; range rescaling needs no readjustment.

Smart Diagnostics + Wide Environmental Tolerance + Easy Installation

mpty-pipe detection with automatic alarm and zeroing; self-diagnostics cover excitation drive, system memory, and overrange faults. Explosion-proof Ex ia/db/eb IIC T4–T6 Gc/Gb, protection IP65/IP67/IP68, ambient temperature –40 °C to +70 °C. Wide power supply AC 100–230 V (±15%) / DC 11–40 V. Magnetic field balancing requires only 5D upstream and 2D downstream straight pipe. RS232/RS485/HART optional, 9-digit forward/reverse/net totalizers, remote and local configuration.

Certifications

    EAC Ex Explosion Protection Certification

    EAC Ex Explosion Protection Certification

    EAC conformity certificate issued by the Eurasian Economic Union (Russia, Kazakhstan, Belarus) under TR CU 012/2011, covering MF series electromagnetic flowmeters for explosive atmospheres.

    CSA c/US Safety Certification

    CSA c/US Safety Certification

    ertified by CSA Group for both Canada and the United States (c/US mark). Covers MFC, MFE-S, and MFD electromagnetic flowmeters to UL/CSA electrical measurement equipment standards, enabling market access in North America.

    HART 7 Communication Registration

    HART 7 Communication Registration

    Certified by FieldComm Group to HART 7 protocol and IEC 61158 standards, enabling automatic device recognition and remote configuration in major DCS systems.

    IECEx Explosion Protection Certification

    IECEx Explosion Protection Certification

    International IECEx certificate (No. IECEx NEP 20.0031X) covering MFC, MFD, and MFE electromagnetic flowmeters with Ex db flameproof, Ex eb increased safety, and Ex ia intrinsic protection for IIC T6/T5 Gb hazardous areas. Recognized across 50+ member countries.

    Applications

    Chemical Industry

    Chemical Industry

    Flow measurement of low-conductivity conductive liquids, mother liquor, and slurry

    Metallurgy

    Metallurgy

    Ore slurry and electrolyte metering

    Power Industry

    Power Industry

    Desulfurization and denitrification slurry, cooling water

    Environmental Protection

    Environmental Protection

    Landfill leachate and industrial wastewater

    Municipal Water

    Municipal Water

    Wastewater, mud, and cement slurry measurement

    Case Studies

    Shandong Hualu-Hengsheng Chemical Co., Ltd.

    Shandong Hualu-Hengsheng Chemical Co., Ltd.

    Domestic Substitution of High-Pressure Electromagnetic Flowmeters for Coal-Water Slurry Gasification Units: Overcoming core challenges in high-frequency excitation and non-stationary signal fusion processing to replace imported instruments.

    Zhejiang Jinli Environmental Protection Paper Industry Co., Ltd.

    Zhejiang Jinli Environmental Protection Paper Industry Co., Ltd.

    1 Million t/a Environmental Recycled Premium Packaging Paper Project: Multi-frequency excitation suppresses slurry noise, applied to pulping and papermaking processes.

    CMOC Group Limited

    CMOC Group Limited

    Scheelite Recovery Production Line of Tungsten Mineral Processing No. 1 Company (11,000 t/d): Applied to flotation and tailings transport processes.

    Downloads

    Brochure

    流量仪表宣传页-中文单页版z

    14.8MB
    Instruction Manual

    CQYC-Electromagnetic-Flowmeter-Operation-Manual-EN

    2026-10-01 28.4
    Product Catalog & Selection Guide

    CQYC-Electromagnetic-Flowmeter-Brochure-EN

    43.1