PDS879 Ultra-High Temperature Remote-Seal Pressure Transmitter
Incorporates a high-temperature-rated remote seal assembly to measure pressure in ultra-high-temperature process media, reducing heat transfer to the sensor and enabling reliable, long-term monitoring in high-temperature processes.
Technical data
| Best measurement accuracy: | ±0.1%FS | Measuring range: Gauge: | -0.1 ~ 10 MPa |
| Maximum turndown ratio: | 20:1 | Process temperature: | +12°C ~ +700°C |
| Pressure rating: | Flange pressure rating: ANSI 150 to ANSI 2500; DIN PN10 to PN160 | Communication protocols: | HART 7, PROFIBUS-PA 3.02, FOUNDATION Fieldbus 6.1.1, Ethernet-APL, AutBus |
| Output signal: | 4–20 mA DC with HART; digital fieldbus signals | Power supply: | 4–20 mA: 10.5 to 45 VDC; HART communication: 15.8 to 45 VDC; PA/FF: 9 to 32 VDC; Ethernet-APL: 9.6 to 15 VDC |
| Long-term stability: | ≤±0.1%FS over 10 years | Body temperature effect at 1:1 turndown: | ≤±0.41%FS/28°C |
| Response time: | ≤90 ms | Ambient temperature: | -40°C ~ +85°C |
| Ingress protection: | IP66/IP67 | Damping setting: | 0 ~ 100 s |
| Electrical entries: | M20×1.5; 1/2 NPT | HART loop load: | 230 ~ 500 Ω |
| Power supply effect: | ≤0.005% of calibrated span/V |
Features & Benefits
Ultra-High Temperature, Demanding Applications
Remote seal assembly designed for process media up to 700°C.
Thermal Insulation, Sensor Protection
Thermal insulation design helps reduce heat transfer from high-temperature media to the sensor.
Configuration Options, Flexible Installation
A range of flange, diaphragm, and capillary configurations available for various mounting requirements.
Reduced Impulse Piping, Easy Maintenance
Avoids maintenance issues associated with conventional impulse piping in high-temperature applications.
Smart Diagnostics, Easy Configuration
Supports intelligent diagnostics and remote configuration.