Features a monocrystalline silicon sensing element with a direct-mount design for gauge and absolute pressure measurement of liquids, gases, and steam. Delivers high accuracy, long-term stability, and intelligent diagnostics.
Technical data
| Best measurement accuracy: | ±0.025%FS | Measuring range: Gauge: | -0.1 ~ 70 MPa; absolute: 0 ~ 20 MPa |
| Maximum turndown ratio: | 100:1 | Process temperature: Silicone oil: | -40°C to ~ 120°C; fluorinated oil: -52°C ~ +120°C |
| Pressure rating: | Maximum overload pressure: 105 MPa | Communication protocols: | HART 7, PROFIBUS-PA 3.02, FOUNDATION Fieldbus 6.1.1, Ethernet-APL, AutBus |
| Output signal: | 4–20 mA DC with HART; digital fieldbus signals | Power supply: | 4–20 mA: 10.5 to 45 VDC; HART communication: 15.8 to 45 VDC; PA/FF: 9 to 32 VDC; Ethernet-APL: 9.6 to 15 VDC |
| Long-term stability: | ≤±0.1%FS over 10 years | Body temperature effect at 1:1 turndown: | ≤±0.07%FS/28°C |
| Response time: | ≤90 ms | Ambient temperature: | -40°C ~ +85°C |
| Ingress protection: | IP66/IP67 | Damping setting: | 0 ~ 100 s |
| Electrical entries: | M20×1.5; 1/2 NPT | HART loop load: | 230 ~ 500 Ω |
| Power supply effect: | ≤0.005% of calibrated span/V |
Features & Benefits
Direct Mounting, Simple Installation
Direct-mount process connection avoids impulse piping and reduces potential leak points.
High Accuracy, Stable Measurement
High-accuracy sensing combined with digital compensation maintains consistent measurement performance.
Multiple Protocols, Easy Configuration
Supports multiple communication protocols including HART, with remote configuration capability.
Smart Diagnostics, Efficient Maintenance
Intelligent diagnostics for monitoring transmitter status and process anomalies.
Material Options, Versatile Applications
Available in multiple wetted materials and explosion-proof configurations.